Ventilation
Jackson,
MS Inspectors
Brandon,
Madison, Jackson, Canton, Ridgeland, Pearl, Florence, Richland, Byram.
Mississippi
New Home Inspector
Order
Agreement
Schedule
Inspection
Get
Your Report
Sample
Reports
Service
and Fees
Be
Prepared
Credit
Helper
Links
________________
Attic
Cooling
Systems
Heating
Systems
Electrical
Fire Place
Roofing
Insulation
Mold
Plumbing
Radon
Lead
Based Paints
Ventilation
Water
Heaters
Whirlpool
Tubs
Home


For
I am the Lord, your God, who takes hold of your right hand and
says to you, Do not fear; I will help you.
Isaiah
41:13
Mississippi
Home Inspectors serving, Brandon, Mississippi,
Byram,
Mississippi,
Flowood,
Mississippi,
Pearl,
Mississippi,
Madison,
Mississippi,
Canton,
Mississippi,
Jackson,
Mississippi,
Ridgeland,
Mississippi,
Richland,
Mississippi,
Rankin
and Hinds County.
Brandon,
Madison, Jackson, Canton, Ridgeland, Pearl, Florence, Richland, Byram.
Mississippi
Home Inspectors
|
|
This
wind turbine attic ventilator is not mounted properly and
will be prone to leak during a heavy rainfall. The base is
adjustable by twisting or rotating to a level position. These
will help exhaust the hot air build up as heat rises. Works
with the soffit vents that allows the cooler shaded air to
enter the attic. Consult a qualified home inspector.
|

This
photo shows the correct wind turbine installation. This view
if from the roof side or exterior of the house. We should also
see a hole cut in the roof decking from inside the attic.
|
This
picture shows ridge vents for attic ventilation. This looks
good from the roof side, however the roof decking should be
cut back from the ridge to allow the hotter attic air to flow
out. You may be able to view the ridge cut out from inside the
attic.
|
This
soffit vent is not cut out properly and does not allow enough
cooler shaded air entry. All to often a common notation on new
construction home inspections. |

Multiple
attic ventilation provisions noted in the photo taken by A
Wise Brandon, Mississippi Home inspector. You can see the two
wind turbines or sometimes called whirly birds and four other
smaller vents that allow heat or in some cases smoke out. You
can view more photos of attic ventilation provisions by
clicking on the photo of the ventilation shown above.
|
This bathroom vent fan cover is stopped up.
Cleaning is recommended. This is a common notation in a home
inspection. |

View
of a power attic ventilator. The advantage of a power attic
ventilator is it can move more cubic feet of air than a wind
turbine and it is thermostatically controlled so it only runs
when the temperature is hot. The down side is the motors fail
often.
A
Wise Inspector Service
Years
of Experience and Thousands of Homes Inspected
601-540-0144
New Home Certified Inspector.
|

This
view of a power attic ventilator shows the wiring is exposed
and not in the thermostat/junction box and missing its cover.
The exposed electrical wiring is a very common notation in
home inspections.
Design, Layout,